Navigate to the device in the Zenoss interface.
From the page menu, select
→ .From the table menu, select Bind Templates.
The Bind Performance Templates dialog appears.
To add the FTPMonitor template and retain other performance templates, hold down the control key while clicking on the FTPMonitor entry.
Click OK.
The FTPMonitor template should now be displayed under the Performance Templates for Device
.
Click the FTPMonitor template and change options as needed. Click to save your changes.
Table 5.2. FTPMonitor Basic Data Source Options
Option | Description |
---|---|
Port | The port to connect to FTP server (default 21) |
Send String | Command string to send to the server |
Expect String | A string to expect in server response |
Mismatch | If the expected string does not match the string returned from the remote server, create an event with one of these states: ok, warn, crit (default: warn) |
Quit String | Command to send to the remote server to end the session |
Navigate to the Perf tab and you should see some placeholders for graphs. After approximately fifteen minutes you should see the graphs start to become populated with information.