Navigate to the device in the Zenoss interface.
From the page menu, select
→ .Select the FTPMonitor template and change options as needed. Click Save to save your changes.
Table 5.4. FTPMonitor Tunables Data Source Options
Option | Description |
---|---|
Timeout | Seconds before connection times out (default: 60) |
Refuse | If a TCP/IP connection to the remote service is refused (ie no program is listening at that port) send an event with one of these severity states: ok, warn, crit (default: crit) |
Max Bytes | Close the connection once more than this number of bytes are received. |
Delay | Seconds to wait between sending string and polling for response |
Warning response time (seconds) | Response time to result in a warning status. |
Critical response time (seconds) | Response time to result in critical status |